• Input signal type:
Thermocouple: K, E, S, B, J, T, R, N and WRe3-WRe25, WRe5-WRe26, etc.;
Thermal resistance: two-/three-wire system thermal resistance (Pt100, Cu50, Cu100, BA1, BA2, etc.)
The type and range of input signal can be determined at the time of ordering or self-programmed.
• Output signal type:
DC: 0(4)mA~20mA;0mA~10mA;
DC voltage: 0(1)V~5V; 0V~10V;
Other signal types may be customized as required, see the product label for the specific signal types;
• Output ripple:<5mV rms(load 250Ω)
• Accuracy of isolated transmission: (25℃±2℃, excluding cold junction compensation)
Input signal type | Range | Accuracy |
TC | K/E/J/N, etc. | < 300 ℃ | ±0.3 ℃ |
≥ 300 ℃ | ±0.1% F∙S |
S/B/T/R/WRe-series | < 500 ℃ | ±0.5 ℃ |
≥ 500 ℃ | ±0.1% F∙S |
RTD | Pt100/Cu100/Cu50/BA1/BA2, etc. | < 100 ℃ | ±0.1 ℃ |
≥ 100 ℃ | ±0.1% F∙S |
Width×Height×Depth(12.7mm×110mm×118.9mm)