Product: Electromagnetic flow meter
Model: SUP-LDG-C
Diameter nominal: DN15~DN1000
Nominal pressure: DN6 – DN80, PN<4.0MPa; DN100 – DN150, PN<1.6MPa; DN200 – DN1000, PN<1.0MPa; DN1200 – DN2000, PN<0.6MPa
Accuracy: ±0.3%,±2mm/s(flowrate<1m/s)
Repetitiveness: 0.15%
Liner material: PFA, F46, Neoprene, PTFE, FEP
Electrode material: Stainless steel SUS316, Hastelloy C, Titanium, Tantalum, Platinum-iridium
Medium temperature: Integral type: -10℃~80℃; Split type: -25℃~180℃
Power supply: 100-240VAC,50/60Hz / 22VDC—26VDC
Electrical conductivity: IP65, IP68(optional)
Product standard: JB/T 9248-2015
Mag meter works based on Faraday’s law, when the liquid goes through the pipe at the flow rate of v with a diameter D, within which a magnetic flux density of B is created by an exciting coil, the following electromotive E is generated in proportion to flow speed v:
E=K×B×V×D
Where:
E-Induced electromotive force
K-Meter constant
B-Magnetic induction density
V-Average flow speed in cross-section of measuring tube
D-Inner diameter of measuring tube